272 research outputs found

    Toward a numerical deshaker for PFS

    Get PDF
    The Planetary Fourier Spectrometer (PFS) onboard Mars Express (MEx) is the instrument with the highest spectral resolution observing Mars from orbit since January 2004. It permits studying the atmospheric structure, major and minor compounds. The present time version of the calibration is limited by the effects of mechanical vibration, currently not corrected. We proposed here a new approach to correct for the vibrations based on semi-blind deconvolution of the measurements. This new approach shows that a correction can be done efficiently with 85% reduction of the artefacts, in a equivalent manner to the stacking of 10 spectra. Our strategy is not fully automatic due to the dependence on some regularisation parameters. It may be applied on the complete PFS dataset, correcting the large-scale perturbation due to microvibrations for each spectrum independently. This approach is validated on actual PFS data of Short Wavelength Channel (SWC), perturbed by microvibrations. A coherence check can be performed and also validate our approach. Unfortunately, the coherence check can be done only on the first 310 orbits of MEx only, until the laser line has been switch off. More generally, this work may apply to numerically "deshake" Fourier Transform Spectrometer (FTS), widely used in space experiments or in the laboratory.Comment: 18 pages, 8 figures, submitted to Planetary and Space Scienc

    Compensation of Thermal Gradients Effects on a Quartz Crystal Microbalance

    Get PDF
    Quartz Crystal Microbalances (QCM) are widely used instruments thanks to their stability, low mass, and low cost. Nevertheless, the sensitivity to temperature is their main drawback and is often a driver for their design. Though the crystal average temperature is mostly considered as the only disturbance, temperature affects the QCM measurements also through the in-plane temperature gradients, an effect identified in the past but mostly neglected. Recently, it has been shown that this effect can prevail over that of the average temperature in implementations where the heat for thermal control is released directly on the crystal through deposited film heaters. In this study, the effect of temperature gradients for this kind of crystal is analyzed, the sensitivity of frequency to the average temperature gradient on the electrode border is determined, and a correction is proposed and verified. A numerical thermal model of the QCM has been created to determine the temperature gradients on the electrode borders. The frequency versus temperature-gradient function has been experimentally determined in different thermal conditions. The correction function has been eventually applied to a QCM implementing a crystal of the same manufacturing lot as the one used for the characterization. The residual errors after the implementation of the correction of both average temperature and temperature gradients were always lower than 5% of the initial temperature disturbance. Moreover, using the correlation between the heater power dissipation and the generated temperature gradients, it has been shown that an effective correction strategy can be based on the measurement of the power delivered to the crystal without the determination of the temperature gradient

    Measurement method for quality control of cylinders in roll-to-roll printing machines

    Get PDF
    This paper describes a measurement method for the quality control of cylinders for printing machines based on roll-to-roll presses. If the surface finishing of the cylinders is not adequate, the printing is unacceptable, and the defective cylinders must be reworked. The performed quality check of the cylinder surface roughness by means of contact methods was unable to identify the cylinder defects, and acceptance of the manufactured cylinders before integration was demanded to the visual inspection performed by trained operators. In this work a contactless measurement method based on the eddy current displacement sensor was proposed and validated as a tool for quality check as an alternative to optical roughness measurements. A test bench for the characterization of printer cylinders was designed and manufactured, allowing for the validation of the proposed method on different batches of cylinders and the identification of a threshold to guide the acceptance of tested cylinders prior to mounting on the roll-to-roll press

    Quartz Crystal Microbalances for Space: Design and Testing of a 3D Printed Quasi-Kinematic Support

    Get PDF
    Outgassing or thruster’s generated contaminants are critical for optical surfaces and optical payloads because scientific measurements and, in general, the performances can be degraded or jeopardized by uncontrolled contamination. This is a well-known issue in space technology that is demonstrated by the growing usage of quartz crystal microbalances as a solution for measuring material outgassing properties data and characterizing the on-orbit contamination environment. Operation in space requires compatibility with critical requirements, especially the mechanical and thermal environments to be faced throughout the mission. This work provides the design of a holding structure based on 3D printing technology conceived to meet the environmental characteristics of space application, and in particular, to face harsh mechanical and thermal environments. A kinematic mounting has been conceived to grant compatibility with a large temperature range, and it has been designed by finite element methods to overcome loading during the launch phases and cope with a temperature working range down to cryogenic temperatures. Qualification in such environments has been performed on a mockup by testing a prototype of the holding assembly between −110 °C and 110 °C and allowing verification of the mechanical resistance and stability of the electrical contacts for the embedded heater and sensor in that temperature range. Moreover, mechanical testing in a random environment characterized by an RMS acceleration level of 500 m/s2 and excitation frequency from 20 to 2000 Hz was successfully performed. The testing activity allowed for validation of the proposed design and opened the road to the possible implementation of the proposed design for future flight opportunities, also onboard micro or nanosatellites. Moreover, exploiting the manufacturing technology, the proposed design can implement an easy assembling and mounting of the holding system. At the same time, 3D printing provides a cost-effective solution even for small series production for ground applications, like monitoring the contaminants in thermo-vacuum chambers or clean rooms, or depositions chambers

    Arbuscular mycorrhizal fungi diversity in revegetated areas after bauxite mining.

    Get PDF
    Arbuscular mycorrhizal fungi (AMF) are obligatory biotrophs that have a symbiotic evolutionary relationship with about 80% of all terrestrial plant species. The fungus mainly supplies water and nutrients to the plant and receives photoassimilates. The AMF diversity affects both the competition among species and floristic composition of an area. Fluctuations in the population of this group of microorganisms can cause fluctuations in plant populations above ground. In this work, the AMF community profile in areas with different ages of revegetation was evaluated by morphological identification of spores and denaturing gradient gel electrophoresis (DGGE) techniques. We found 12 AMF species and dominance of the species Glomus macrocarpum determined by spore density. Since the richness level observed in each plot was low and there was predominance of one species of AMF, it can be concluded that these areas still present a high degree of disturbance. It was possible to detect complex band profiles by DGGE analyses for the two plant species studied, Visnia latifolia and Cecropia hololeuca. No relationship between AMF diversity and revegetation time was observed in these areas

    Developing cardiac and skeletal muscle share fast-skeletal myosin heavy chain and cardiac troponin-I expression

    Get PDF
    Skeletal muscle derived stem cells (MDSCs) transplanted into injured myocardium can differentiate into fast skeletal muscle specific myosin heavy chain (sk-fMHC) and cardiac specific troponin-I (cTn-I) positive cells sustaining recipient myocardial function. We have recently found that MDSCs differentiate into a cardiomyocyte phenotype within a three-dimensional gel bioreactor. It is generally accepted that terminally differentiated myocardium or skeletal muscle only express cTn-I or sk-fMHC, respectively. Studies have shown the presence of non-cardiac muscle proteins in the developing myocardium or cardiac proteins in pathological skeletal muscle. In the current study, we tested the hypothesis that normal developing myocardium and skeletal muscle transiently share both sk-fMHC and cTn-I proteins. Immunohistochemistry, western blot, and RT-PCR analyses were carried out in embryonic day 13 (ED13) and 20 (ED20), neonatal day 0 (ND0) and 4 (ND4), postnatal day 10 (PND10), and 8 week-old adult female Lewis rat ventricular myocardium and gastrocnemius muscle. Confocal laser microscopy revealed that sk-fMHC was expressed as a typical striated muscle pattern within ED13 ventricular myocardium, and the striated sk-fMHC expression was lost by ND4 and became negative in adult myocardium. cTn-I was not expressed as a typical striated muscle pattern throughout the myocardium until PND10. Western blot and RT-PCR analyses revealed that gene and protein expression patterns of cardiac and skeletal muscle transcription factors and sk-fMHC within ventricular myocardium and skeletal muscle were similar at ED20, and the expression patterns became cardiac or skeletal muscle specific during postnatal development. These findings provide new insight into cardiac muscle development and highlight previously unknown common developmental features of cardiac and skeletal muscle. © 2012 Clause et al

    MicroMED: an optical particle counter for the direct in situ measurement of abundance and size distribution of dust suspended in the atmosphere of Mars

    Get PDF
    The MicroMED experiment has been developed for the characterization of airborne dust close to the surface of Mars and is suitable to be accommodated on Martian landers or rovers. It is an optical particle counter, analyzing light scattered from single dust particles to measure their size and abundance. An Elegant Breadboard of the instrument has been realized and successfully tested in a Martian simulated environment. Test results demonstrate the expected functionality and performances of the experiment. <P /
    • 

    corecore